OPERATING MANUAL
VERSION 10/2013
ORDER NUMBER DOC 2303675
3.1 EXPLOSION PROTECTION IDENTIFICATION
As de ned in Directive 94/9/EC (ATEX 95), the device is suitable for use in potentially explosive
areas.
European Communities
Symbol for explosion protection
Device class II
Category 2 (Zone 1)
Ex-atmosphere gas
Explosion group
Constructional safety
Special Notes (see Chapter 3.2)
3 IDENTIFICATION
3.2 IDENTIFICATION X
X The maximum surface temperature corresponds to the permissible product
temperature. This and the permissible ambient temperature can be found in the
"Technical Data" chapter.
Maximum surface temperature
The maximum surface temperature of the pump depends on the operating conditions
(heated product) and not on the device (frictional heat).
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Ambient temperature
The permissible ambient temperature is: +10 °C to +60 °C; +50 °C to 140 °F.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g. air.