VIVOTEK
User's Manual - 141
paritybit none,
odd,
even
4/4 For error checking.
stopbit 1,2 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
4/4 RS485 or RS232.
customdrvcmd_i<0~9> string[128] 1/4 PTZ command for custom camera.
speedlink_i<0~4>_name string[40] 1/4 Additional PTZ command name.
speedlink_i<0~4>_cmd string[128] 1/4 Additional PTZ command list.
ptzdriver 0~19,
127 (custom),
128 (no driver)
4/4 The PTZ driver is used by this COM port.
7.22 SNMP
Group: snmp (capability.snmp > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
v2 0~1 6/6 SNMP v2 enabled. 0 for disable, 1 for enable
v3 0~1 6/6 SNMP v3 enabled. 0 for disable, 1 for enable
secnamerw string[31] 6/6 Read/write security name
secnamero string[31] 6/6 Read only security name
authpwrw string[8~128] 6/6 Read/write authentication password
authpwro string[8~128] 6/6 Read only authentication password
authtyperw MD5,SHA 6/6 Read/write authentication type
authtypero MD5,SHA 6/6 Read only authentication type
encryptpwrw string[8~128] 6/6 Read/write password
encryptpwro string[8~128] 6/6 Read only password
encrypttyperw DES 6/6 Read/write encryption type
encrypttypero DES 6/6 Read only encryption type
rwcommunity string[31] 6/6 Read/write community
rocommunity string[31] 6/6 Read only community
syslocation 0~128 6/6 System location
syscontact 0~128 6/6 System contact