Vista -10SE Home Security System User Manual


 
VISTA-10SE Installation and Setup Guide
14-10
Important Note: If 15 is entered in field
95 to bypass an answering machine,
and a 4285/4286 VIP Module is included in the installation, you should note the
following:
When calling in from an off-premises phone (to receive a status report or execute a
command), the user should make the initial call, allow 1 to 3 rings only, and hang
up. Then call in again. The VIP Module will now seize the line, and 2 long tones
will be heard, followed by the usual voice prompt for the 2-digit phone access code.
If this procedure is not followed, VIP Module operation will not be possible.
96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO.
FOR DOWNLOADING
(No data entry required; press
96)
97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES
(No data entry required; pressing
97 automatically loads all
ADEMCO defaults). Do not use if previously programmed with other
values.
TO EXIT
PROGRAMMING
MODE
(
98 or
99)
98 EXITS PROGRAMMING MODE
and
prevents
re-entry by :
INSTALLER Code + 8 + 0.
To enter the Programming mode if
98 was used to exit, you must
first power the system down. Then power-up again, and depress [
]
and
[#] both at once, within 50 seconds of powering up.
99 EXITS PROGRAMMING MODE
and
allows
re-entry by:
INSTALLER Code + 8 + 0 or by method described in paragraph
above (power down, power-up and depress [
]
and
[#] both at once,
within 50 seconds of powering up).