VISTA-10SE Installation and Setup Guide
14-10
Important Note: If “15” is entered in field
✱
95 to bypass an answering machine,
and a 4285/4286 VIP Module is included in the installation, you should note the
following:
When calling in from an off-premises phone (to receive a status report or execute a
command), the user should make the initial call, allow 1 to 3 rings only, and hang
up. Then call in again. The VIP Module will now seize the line, and 2 long tones
will be heard, followed by the usual voice prompt for the 2-digit phone access code.
If this procedure is not followed, VIP Module operation will not be possible.
✱
96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO.
FOR DOWNLOADING
(No data entry required; press
✱
96)
✱
97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES
(No data entry required; pressing
✱
97 automatically loads all
ADEMCO defaults). Do not use if previously programmed with other
values.
TO EXIT
PROGRAMMING
MODE
(
✱
98 or
✱
99)
✱
98 EXITS PROGRAMMING MODE
and
prevents
re-entry by :
INSTALLER Code + 8 + 0.
To enter the Programming mode if
✱
98 was used to exit, you must
first power the system down. Then power-up again, and depress [
✱
]
and
[#] both at once, within 50 seconds of powering up.
✱
99 EXITS PROGRAMMING MODE
and
allows
re-entry by:
INSTALLER Code + 8 + 0 or by method described in paragraph
above (power down, power-up and depress [
✱
]
and
[#] both at once,