Vista -10SE Home Security System User Manual


 
Section 13 Zone Response Type Definitions
13-3
Type 20
ArmSTAY
Zone type 20 is a special-purpose zone type used with 5800 Series wireless
pushbutton transmitters.
Zone Characteristics:
Exit delay regardless of the arming mode selected.
System is armed in the STAY mode when the zone is activated.
Zone number is sent to the central station as a user number when
arming or disarming.
Type 21
ArmAWAY
Zone type 21 is a special-purpose zone type used with 5800 Series wireless
pushbutton units.
Zone Characteristics:
System is armed in the AWAY mode when the zone is activated.
Zone number is sent to the central station as a user number when
arming or disarming.
Type 22
Disarm
Zone type 22 is a special-purpose zone type used with 5800 Series wireless
pushbutton.
Zone Characteristics:
Disarms the system when the zone is activated.
Type 23
No Alarm Response
Zone type 23 can be used when the action of a relay is desired, but with no
accompanying alarm (e.g., a front or back door light being turned on or off).