Vista -10SE Home Security System User Manual


 
VISTA-10SE Installation and Setup Guide
14-2
26 VOICE (PHONE) MODULE ACCESS CODE (2-Digit Entry)
The use of a 4285 or 4286 VIP (Phone) Module requires a 2-digit code. Enter a
2-digit phone access code as follows: For first digit, enter any digit from 1 to
9; for second digit, enter # +11 for
,
or # +12 for #.
Example: If the desired access code is 7
,
7
is the first entry, and # + 11 (for
) is the second entry.
00 = VIP Module disabled. Note: A 0 in either digit will disable the
4285/4286 VIP Module.
27 OUTPUT TO LONG-RANGE RADIO (1-Digit Entry)
0= no, 1 = yes. If output to LRR is selected here (1), all messages that are
programmed to go to the primary telephone line receiver will also be sent to
the radio (e.g., 7720 PLUS). These messages will always be in Contact ID
format (overriding the selection in field
46). The data line is supervised, as
well as certain functions in the radio.
If communication is lost or a trouble develops, the system will attempt to
send a message via both radio and telephone to the central station.
Normal trouble restore report (
71) is sent on restore of the condition.
NOTE: The Radio should be programmed for device address 3 on the keypad
lines.
ZONE SOUNDS
AND TIMING
(
28
39)
28 SINGLE ALARM SOUNDING PER ZONE
(Per Armed Period) (1-Digit Entry)
This field limits external alarm sounding to once per arming period for a
given zone. Enter 1 for yes; 0 for no.
UL installations: Enter 0 for unlimited alarm soundings.
29 FIRE SOUNDER TIMEOUT (1-Digit Entry)
This field determines whether the external sounder will shut off after time
allotted, or continue until manually turned off.
Enter 0 for sounder timeout, or 1 for no timeout.
Default is 0.
30 ALARM BELL TIMEOUT (1-Digit Entry)
This field determines whether the external sounder will shut off after time
allotted, or continue until manually turned off. Enter as follows:
0 = No timeout; 1 = 4 min (default); 2 = 8 min; 3 = 12 min; 4 = 16 min.
38 ENTRY DELAY (1-Digit Entry)
System will wait the time allotted before sounding alarm upon entering. May
be selected individually.
0 = 0 seconds; 1 = 20 seconds; 2 = 30 seconds; 3 = 45 seconds;
4 = 60 seconds; 5 = 90 seconds.
UL installations: Entry delay can be no greater than 45 seconds (3).
(EXIT delay = Entry delay plus 15 seconds).