SEALED SYSTEM
The sealed system consists of the following components (listed in order of refrigerant
flow):
1 condenser coil
1 dryer assembly
3 solenoid valves
3 heat exchangers
3 evaporators
1 compressor
1 discharge tube
1 drain pan heater
1 pre-condenser loop
Refrigerant Type – HFC 134a
Refrigerant Charge – 7.3 oz.
Evaporator Temperature Range
14°F to - 31°F
Expanding Device – Cap tube
Compressor Cooling:
LBP 32° C Ambient temp 98 to 140V
LBP 43° C Ambient temp 98 to 140V
Maximum Condensing Pressures:
Operating 230 psig
Peak 293 psig
Electrical Data:
Normal Voltage 115VAC / 60Hz
Start Winding Resistance – 21.20 (at
77°F) ± 8%.
Run Winding Resistance – 7.90 (at
77°F) ± 8%.
Locked Rotor Amps (60Hz) – 9.80
Amps.
Full Load Amps (60Hz) – 1.20 Amps.