Utica PEG-C Thermostat User Manual


 
LIGHTING PROCEDURE FOR BOILER WITH
INTERMITTENT PILOT SYSTEM.
FOR YOUR SAFETY READ BEFORE OPERATING.
A. This appliance is equipped with an ignition system which automatically lights the pilot.
Do not try to light the pilot by hand.
B. Before operating smell all around the appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than air and will settle on the floor.
CAUTION: WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch.
* Do not use any phone in your building.
* Immediately call your gas supplier from a neighbor's phone.
* Follow your gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire department.
PAGE 11
THERMOSTAT INSTALLATION
1. Thermostat should be installed on an inside wall at least two feet from an uninsulated
or outside wall, approximately four feet above the floor.
2. NEVER install a thermostat on an outside wall.
3. Do not install a thermostat where it will be affected by:
A. Drafts
B. Hot or cold pipes
C. Sun light
D. Lighting fixtures
E. Television
F. Fireplace or chimneys
4. Check thermostat operation by raising and lowering thermostat as required to start
and stop the burners.
5. Instructions for the final adjustment of the thermostat are packaged with the
thermostat ( adjusting heating anticipator, calibration, etc.).
LIGHTING INSTRUCTIONS
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EX-
ACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
Before any procedures are attempted on this appliance, it is necessary to
determine if the ignition system is intermittent or continuous pilot system. If you are
uncertain, contact the manufacturer before proceeding.
CAUTION: Before operating, make certain steam boiler is full of water
to water line and system is vented of air. See the operating lighting instructions.