30
Toshiba
6-5. Outdoor Control Board
HWS-802H-E
Electrolytic capacitors
Reactor connection connecto
r
Compressor output terminals
CN202
CN201
CN200
Fan motor output
CN300 (White)
Case thermostat connector
CN609(Blue)
4-way valve connector
CN701(White)
Compressor ON
output connector
CN704(
Blue
)
Heater output connector
CN703(Grey)
External input connector
CN610(Yellow)
Special operation switches
SW801
SW804
Display change-over switches
SW800
SW803
Temperature sensor connectors
TL CN604(
White
)
TD CN603(
White
)
TO CN602(
Yellow
)
TE CN601(
White
)
TS CN600(
White
)
Alive, error display LEDs
D800 804(
Yellow
)
D805(
Green
)
PMV connector
CN710 (White)
Initialization switch
SW802
Power circuit protection
fuse
F01 (250V, 25A)
Connecting cable connector
CN04(White)
Connecting cable protection fuse
F03 (250 V, 10 A)
Earth lead wire
P09 (Black)
Power supply connection lead
wires
P01(Red)
P02(White)
Hydro-outdoor communication signal LEDs
D503 (Green, Outdoor => Hydro)
D502 (Amber, Hydro => Outdoor)
4-way valve protection
fuse
F700 (250 V, 3.15 A,
plastic case)
Power circuit protection
fuse
F100 (250 V, 3.15 A,
plastic case)
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 30 Monday, October 5, 2009 2:09 PM