144
Toshiba
6 Compressor
Compressor lead
3. Vacuuming
1)Connect the vacuum pump to the charge port of
the gas piping valve to operate the vacuum pump.
2)Perform vacuuming until the vacuum low pressure
gauge shows 1(mmHg).
Note)
Open fully the pulse motor valve before
vacuuming. With the valve closed, vacuuming
between the outdoor unit liquid valve and the pulse
motor valve may fail.
How to make pulse motor valve forcible full open
• Turn on the electric leakage breaker.
• Set the SW804 dip switch 1 and 3 on the outdoor
unit control board to ON.
• Press SW801 on the outdoor unit control board
for 1 second or longer.
• After pressing SW801 for 1 second or longer,
turn off the electric leakage beaker within 2
minutes.
4. Charge refrigerant
1)Add refrigerant whose amount is defined
according to the piping length from the valve
charge port. (HWS-802H : 1.8kg)
7 Pulse motor valve coil
1. How to remove
1)Perform the step 1-1 and step 3.
2)Remove the coil from the pulse motor valve body
while pulling the coil upward to release the spring
holding the copper pipe.
2. How to attach
1)Fix the spring to the copper pipe.
No.
Exchange parts
name
Work procedure Remarks
SW801SW804
Pulse motor
valve body
Pulse motor valve coil
Spring
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 144 Monday, October 5, 2009 2:09 PM