Slant/Fin J-390 Boiler User Manual


 
Jaguar Model J-390
9
JAGUAR J-390 NON-DIRECT VENT, SIDEWALL VENTING
All joints must be liquid and pressure tight. Use 4” dia. PVC/CPVC schedule 40 pipe or U/L listed single wall 4" dia.
AL29-4C S.S.*. venting materials (See page 7).
AIR INTAKE
(
DO NOT BL0CK)
A
U/L LISTED FLASHING
AND SEAL ING BOOT MUST
BE USED ON COMBUSTIBLE
W
ALLS.
4
IN. DIA.
P
VC/CVPC
PIPE FO R
V
ENT
T
ERMINATION 90 ELBOW
WITH SC REEN
SNOW LINE
(
SEE DEFINITION)
OUTSIDE WALL
SLOPE UP 1/4 IN.
P
ER FOOT MIN.
FROM BOILER TO
V
ENT TERMINA TIO N
9
0 ELBOW
6" MIN.
1
0" MAX.
12" MIN
Figure 6. Non-direct vent, side wall venting - utilizing PVC/CPVC pipe for venting.
(DO NOT BL0CK)
AIR INTAKE
90 ELBOW
STANDARD
VENT TERMINATION
FROM BOILER TO
PER FOOT MIN.
SLOPE UP
1/4 IN.
VENT
MATERIAL FOR
STEEL VENTING
STAINLESS
4 INCH. DIA.
OUTSIDE VENT TERMINATION
ELBOW WITH SCREEN
OUTSIDE WALL
SNOW LINE
(SEE DEFINITION)
6" MIN
10" M AX
12" MIN
WALL THIMBLE MUST BE USED
ON C OM BUSTIBLE WALLS
Figure 7.
Non-direct vent, side wall venting - utilizing stainless steel vent materials for venting.
*
AL 29-4C IS A REGISTERED
TRADEMARK OF ALLEGHENY LUDLUM CORP
.
** Definition of Sno
w Line:
Kno
wledge of local conditions will re
v
eal the maxim
um height that repeated sno
wf
alls accumulate to.
The height should be used as the SNOW LINE.