Slant/Fin J-390 Boiler User Manual


 
Jaguar Model J-390
11
JAGUAR J-390 NON - DIRECT VENT, UTILIZING AN EXISTING
CHIMNEY AS A CHASE
All joints must be liquid and pressure tight. Use 4” dia. PVC/CPVC schedule 40 pipe or U/L listed single wall 4" dia.
AL29-4C S.S.*. venting materials (See page 7).
CHIMNEY
T
OP PLATE
VENT TERMINATION
T
EE WITH SCREEN
VENT
VENTING MATERIAL F OR
PIPE OR STAINLESS STE EL
4 INCH DIA. PVC/CPVC
SEAL CHIMNEY OPENING
VENT
VENTING MATERIAL FOR
PIPE O R STAINLESS STEEL
4 INCH DIA. PVC /CPVC
WITH MOR TAR O R COVER PLATE
45°ELBOW
R
AIN CAP TERMINATION MAY BE USED
ALTERNATE VERTICAL TERMINATION
*
E
LBOW WITH SCREEN
9
0°TERMINATION
PER FOOT MIN.
SLOPE UP
1/4 IN.
90°ELBOW
(DO NOT BLOCK)
AIR INTAKE
*
1FT.MIN
10 FT. MIN
Figure 9. Jaguar J-390 - non-direct vent, utilizing an existing chimney as a chase.
*
AL 29-4C IS A REGISTERED
TRADEMARK OF ALLEGHENY LUDLUM CORP
.