Slant/Fin J-390 Boiler User Manual


 
Jaguar Model J-390
12
JAGUAR J-390 - DIRECT VENT, SIDEWALL VENTING
All joints must be liquid and pressure tight. Use 4” dia. PVC/CPVC schedule 40 pipe or U/L listed single wall 4" dia.
AL29-4C S.S.*. venting materials (See page 7).
SLANT/FIN VENT/AIR INTAKE
TERMINATION KIT PART # 83 0802 000
AIR INTAKE LOUVERS
SNOW LIN E ** (SEE DEFINITION)
OUTSIDE WALL
4" DIA PVC/CPVC PIPE FOR AIR INTAKE
3
" - 14" THICK WALL
90°ELBOW
4" DIA PVC/CPVC FLUE PIPE
4" DIA PVC/CPVC COUPLING WITH SCREEN
Figure 10. Direct vent, sidewall venting illustration; utilizing PVC/CPVC pipe for venting
Figure 11.
Direct vent,
side
wall venting illustration;
utilizing stainless steel vent materials f
or venting.
*
AL 29-4C IS A REGISTERED
TRADEMARK OF ALLEGHENY LUDLUM CORP
.
** Definition of Sno
w Line:
Kno
wledge of local conditions will reveal the maximum height that repeated snowfalls accumulate to.
The height should be used as the SNOW LINE.
SLANT/FIN VENT/AIR INTAKE
TERMINATION KIT PART # 83 0802 000
TOGETHER WITH SPECIAL KIT FOR
STAINLESS STEEL VENT PIPE
AIR INTAKE LOUVERS
4" DIA STRIGHT SCREENED VENT TERMINATION
SNOW LINE ** (SEE DEFINITION)
OUTSIDE WALL
ADAPTOR
4" DIA STAINLESS STEEL
PIPE FOR VENT
90°ELBOW
4" DIA PVC/CPVC PIPE FOR AIR INTAKE
3" - 14" THICK WALL