Regency P33S-NG4 Indoor Fireplace User Manual


 
Regency P33 Sunrise
TM
Gas Fireplace 9
INSTALLATION
INSTALLATION
Caution Requirements
The top, back and sides of the replace are de ned by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this replace and vent
system be installed only in accordance with these instructions.
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this replace and vent system be installed only in accordance with these instructions.
C
Clearance: Dimension Measured From:
A: *Front Floor Clearance (min.) 12" (304mm) Underside of Unit
B: *Sidewall (on one side) 7-1/2" (241mm) Side of Unit
C: *Ceiling
(room and/or alcove)
30" (889mm) Top of Unit
D: Alcove Width 48" (1219mm) Sidewall to Sidewall (Minimum)
E: Alcove Depth 36" (914mm) Front to Back Wall (Maximum)
B
C
Close to Ceiling
Flue Clearances
Horizontal - Top 2-1/2"
Horiztonal - Side 1-1/2"
Horiztonal - Bottom 1-1/2"
Vertical (Flex Vent) 1-1/2"
Vertical (Rigid) 1-1/4"
*Note: All measurements are from the top/side of the unit, not optional front.