Regency P33S-NG4 Indoor Fireplace User Manual


 
Regency P33 Sunrise
TM
Gas Fireplace
10
INSTALLATION
INSTALLATION
MANTEL CLEARANCES
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances from side of unit
as per diagram:
Drywall
Mantel Clearances
2
0
12
6
4
810
2
0
12
6
4
8
10
Top of
Unit
12" (305mm)
0” - 3-1/2" (89mm)
7-1/2"(191mm)
11"(279mm)
7"(178mm)
9"(229mm)
41"(1041mm)
to floor
or 29”(737mm)
to base of unit
3"(76mm)
Standoff
Side View
Due to the extreme heat this replace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.