Regency P33S-NG4 Indoor Fireplace User Manual


 
Regency P33 Sunrise
TM
Gas Fireplace
4
INSTALLATION
SAFETY LABEL
This is a copy of the label that accompanies
each P33 Sunrise™ Direct Vent Gas Fireplace.
We have printed a copy of the contents here for
your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
343
343
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
NATURAL GAS: Model P33S-NG4
PROPANE: Model P33S-LP4
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
DOOR SEAL: Please check that
the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Ceiling Clearances from
Top of Unit:
Side Wall Clearance from
Side of Unit:
Top, sides, bottom and rear of unit
(A) 30" (762mm)
B) 7.5"(190mm)
Floor Clearance:
C) 12”(305mm)
D) Max. Depth 36" (914mm)
E Min. Width 48" (1219mm)
Alcove Clearances
)
(See Instruction Manual for Detailed Instructions)
Serial No./ No de serie
918-761
5" WC (1.25 kPa)
3.5" WC (0.87 kPa)
1.6" WC (0.39 kPa)
# 47 DMS
0-4500 ft/pi (0-1372 m)
12,000 Btu/h (3.51 kW)
17,000 Btu/h (4.98 kW)
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle P33S-NG4
ééé
é
é
é
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle P33S-LP4
ééé
é
é
é
VENTING: Use listed Direct Vent Pro and others as listed in the manual or Regency Direct Vent System. Only for direct discharge without duct connection. This appliance
must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the currentANSI Z223.1inthe
USAor the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent SystemAppliance must be installed in accordance with
the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard
for Fire Safety Criteria for Manufactured Home Installations, Sites, and CommunitiesANSI/NFPA501A, and with CAN/CSA Z240 MH Mobile Home
Standard in Canada Certified for use with Heat Wave (Kit # 946-556).
Fan (Part # 432-917) This vented gas fireplace heater is not for use with air filters.
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMESAFTER FIRST SALE.
Listed:
Certified for/Certifi e pour:
Tested to:
WN# 16073
VENTED GAS FIREPLACE HEATER
CANADAand U.S.A.é
CAN/CGA-2.17-M91,
ANSI Z21.88a-2007/CSA2.33a-2007.
Model/Modele:
P33S-NG4
Model/Modele:
P33S-LP4
Electrical supply 115VAC, 1.13A, 60Hz.
Not for use with solid fuel.
Made in Canada/
Fabrique au Canada
Duplicate S/N
Ceiling
Wall
Wall
11" WC (2.73 kPa)
10" WC (2.49 kPa)
6.4" WC (1.59 kPa)
# 56 DMS
0-4500 ft/pi (0-1372 m)
12,000 Btu/h (3.51 kW)
15,500 Btu/h (4.54 kW)
C
E