Regency P33S-NG4 Indoor Fireplace User Manual


 
Regency P33 Sunrise
TM
Gas Fireplace 33
INSTALLATION
WIRING DIAGRAM
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue ame or
close for a more yellow ame.
Minimum Air Shutter Opening:
NG 1/16"
LP 1/4"
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
INSTALLATION
6”
(152mm)
Openings for
electrical connections
120 V. Power IN
Millivolt Wires
4-1/2”
(114mm)
7/16”
(11mm)
2-5/16”
(59mm)
Ground
Green
Neutral
Live
Black Red Red
Minimum Convection
Air Temp. Switch
Ground
ON OFF
Rotary Speed
Control
120VAC
60 Hz
Fan
To Thermocouple IN
Pilot
Assembly
H
I
L
O
O
F
F
O
N
P
I
L
O
T
Gas Pilot
Thermopile
Thermocouple
Electrode
Lockwasher
Fan
ground wire
Nut
#8 Ground Lug
(mobile home
approved)
Star washer
Remote Transmitter
(Optional)
ON OFF
Regency
Remote Receiver
or Thermostat
(Millivolt) (Optional)
Brown
Red
Black
White
"S.I.T" Valve
Burner
ON
OFF
(To THTP)
(To TH)
Gas
In
DC Spark
Box
Ground
(To THTP)
(To TH)