INSTALLATION
INSTALLATION
Before
After
Bend
here
Top Standoff
(flat shipping
position)
Top Standoff
after bending
The Top Facing Support, the Side Nailing Strips
and the 2 Top Standoffs must be correctly
positioned and attached to the top before the
unit is put into position.
Top Standoff Assembly
The top standoffs are shipped in a at position
and must be pulled up and bent into the correct
shape.
1) Remove the standoffs from on top of the
rebox by undoing the screws.
2) Take each standoff and bend into the correct
shape. Bend up at the bend lines until the
screw holes in the standoff and the pre-
punched screw holes on the rebox top
line-up.
3) Attach the standoffs securely to the top with
4 screws per standoff.
Note: Secure the standoffs to the holes
closest to the edge of the rebox top.
Top Facing Support &
Side Nailing Strips
Determine the total thickness of facing material
(e.g. drywall, wood plus ceramic tiles) to allow
the nished surface to be ush with the front of
the unit. Total facing thickness can vary from
1/2" (13mm) to 1-1/4" (32mm) thick.
The Top Facing Support & Side Nailing Strips
can be mounted in various positions depending
on the thickness of the facing material.
1) Mount Top Facing Support using the 3
supplied screws into the three pre-punched
screw holes on the top front of the unit. Adjust
support to desired facing material depth.
2) Mount Side Nailing Strip using the 3
supplied screws into the three pre-punched
screw holes at the front sides of the unit.
Adjust support to desired facing material
thickness.
UNIT ASSEMBLY PRIOR TO INSTALLATION
Side
Nailing
Strip
Top Facing
Support
VENTING INTRODUCTION
The P33 Sunrise™ uses the "balanced ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while
the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion
and losing warm room air up the chimney.
There are 5 vent systems approved for use with the P33S: the Regency
®
Direct Vent Flex System for Horizontal Terminations only and the Simpson
Dura-Vent, Selkirk Direct-Temp, Amerivent Direct Vent and Security Secure Vent Systems for Horizontal and Vertical Terminations (see following
"Venting" Sections for more details).
Note: These ue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate
solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
(See "Rigid Pipe Venting System" for more details and exceptions).
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
For a facing material depth of
1-1/4"(32mm), the top facing
support must be reversed.