MAINTENANCE
MAINTENANCE
12) Unplug the green (TH) and white (TP/TH)
wires from the valve.
13) Disconnect the 2 DC Spark generator wires
from the DC spark box located in front of
the valve.
14) Disconnect the spark electrode wire from
the DC spark box.
Disconnect 2 wires
Disconnect 2 generator wires
DC Spark Box Electrode Wire
Valve Tray Out
Location of Screws.
15) Remove the 16 screws that hold the valve
tray to the rebox and slightly pull out the
valve tray.
17) Replace the valve tray and reverse steps
to re-install.
18) Turn on the gas supply and check for gas
leaks.
19) Re-install the inner panels.
20) Re-install the burner.
21) Re-install the pilot shield.
22) Re-install the glass door.
23) Re-install the faceplate.
24) Check the inlet and outlet pressures.
25) Check operation of fl ame control.
26) Check for proper fl ame appearance.
11) Disconnect the inlet gas line from the
valve.
16) Completely pull out the valve tray.