INSTALLATION
INSTALLATION
16) Install the enclosed identifi cation label to the
valve body where it can be easily seen.
17) Attach the LP conversion decal near or
on top of the serial no. decal.
18) Replace yellow "Natural Gas" label with red
"Propane" label.
19) Adjust the burner aeration setting to the LP
setting (5/16") and
re-install the burner tube.
20) Re-install the burner.
21) Re-install the Pilot Shield cover plate.
22) Re-install the glass door.
23) Re-install the faceplate
24) Continue with completing unit installation.
NOTE: Once the unit has been installed;
a) Turn on the gas supply and check for gas
leaks.
b) Check the inlet and outlet pressures.
c) Check operation of fl ame control using
the remote control.
d) Check for proper fl ame appearance.
Installer Notice:
These instructions must be left
with the appliance.
WARNING!
Do not overtighten the screw.
Recommended to grip
the wrench by the short side.
8) Turn control knob to the “OFF” position.
9) Remove the black protection cap by hand
from the high-low knob (Fig.1).
10) Insert a 5/32” or 4mm Allen wrench into
the hexagonal key-way of the screw (Fig.
2), rotate it counter-clockwise until it is free
and extract it.
11) Check that the screw is clean and if
necessary remove dirt.
12) Flip the screw (Fig. 3).
13) Using the Allen wrench as shown in Fig.4,
rotate the screw clockwise until snug, do
not overtighten.
14) Verify that if the conversion is from NG to
LPG, the screw must be re-assembled with
the red o-ring visible (Fig. 5).
15) Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and
main burner injectors
are appropriate for the gas type.
Fig. 1
Fig.2
Fig.3
Fig.4
LPG Configuration
Red o-ring visible
Fig.5