INSTALLATION
INSTALLATION
FINISHING
1) Finishing material such as tile, river rock, etc. must not protrude
beyond the front facing fl anges on all 4 sides of the fi rebox opening.
2) If material such as brick, stone, etc. extends past the faceplate depth,
when fi nishing around the faceplate, the minimum opening dimension
noted below (Diagram 3) must be adhered to - to ensure the faceplate
can be removed.
36 -1/4”
34 -9/16”
NON-COMBUSTIBLE REQUIREMENTS
47-5/8"
(1209mm)
6-7/16"
(163mm)
3"
(76mm)
32-1/16”
(814mm)
15-9/16"
(392mm)
29-1/16”
(738mm)
31-5/8"
(803mm)
44-1/2"
(1130mm)
Non-combustible
Material
Non-combustible Material
Non-combustible
Material
Non-combustible
Material
Metal
Stud
Finished Floor
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Important:
A 3/4" gap must be maintained all around the outer edge of
the faceplate and the edge of any fi nishing material thicker than
1-1/4" (see diagram 4).
This gap is required to facilitate the installation of the faceplate and
to ensure the removal of the faceplate for service access.
Note: All non-combustible facing material should butt up cleanly to
the fl anges around the fi rebox opening.
Rough edges may be visible, from an angle, through the 1/2" gap
behind the faceplate.
To obtain a clean edge, facing material edges may be fi nished
with a J-style trim or metal cornerbead (both materials available
at your local building or hardware outlet) see diagram 2.
Important: Materials used must be NON-COMBUSTIBLE
3/4"
Finishing Material
(thickness + 1-1/4")