Regency L676S-NG1 Indoor Fireplace User Manual


 
Regency® L676S Direct Vent Gas Fireplace 15
INSTALLATION
INSTALLATION
Vent restriction is required for certain venting
installations, see the diagrams in the "Venting
Arrangements" section to determine if they are
required for your installation.
The Vent Restrictor plate is located on the inside
top of the fi rebox.
VENT RESTRICTOR POSITION
Screws for plugging the holes.
(all holes must be plugged with a screw).
Screw holes for fi xing the restrictor plate.
Vent Restrictor Plate
To set the vent restriction as indicated in the
venting arrangements diagrams, refer to the
following instructions;
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b. Swing the door out from the top and release
the hinge on the left side of the door and
lift out.
Latch
Latch Location
3) Remove the screws that hold the vent
restrictor plate in place.
4) Adjust the vent restrictor plate to the required
vent restrictor position as per the diagrams
shown.
5) Once the vent restrictor plate is in the required
position, secure with screws.
Door
Hinge
1) Remove the faceplate.
2) Remove the glass door.
2- ½”
Vent Restrictor Set 1
Vent Restrictor Set 2
Vent Restrictor Set 3
2”
1- 1/
4
Factory Set Vent Restrictor Set