MAINTENANCE
MAINTENANCE
VALVE TRAY REPLACEMENT
c. Place the door on a soft surface to prevent
scratching the surface.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b. Swing the door out from the top and release
the hinge on the left side of the door and
lift out.
Latch
Latch Location
Door
Hinge with door removed.
1) Shut off the gas supply to the unit.
2) Remove the faceplate.
3) Remove the glass door.
5) Remove bolt on the clip holding in right
inner panel.
6) Lift out right panel.
7) Repeat process for left side.
8) When side panels have been removed, tilt
back panel towards front of fi rebox.
9) Lift back panel up and out from slots to
remove.
10) Remove bolts to lift out the fi rebox base.
Slots for back panel
4) Remove the pilot shield and burner assembly.
(see page 28 for removal instructions).