Regency L234-LP Indoor Fireplace User Manual


 
Regency
®
L234 Direct Vent Gas Insert
34
MAINTENANCE
MAINTENANCE
VALVE REPLACEMENT
1) Open the left and right side faceplate
panels.
2) Remove the bottom louver by pulling out.
3) Remove the glass door.
a) Pull off the left side spring hook that holds
the door in place. While holding the hook turn
it upside down and place it into the middle
opening on the top side mounting bracket.
Repeat for right side.
b) Swing the door out 45 degrees and lift up
and out.
7) Disconnect the gas connection to the
valve.
8) Disconnect the ignitor wire from the DC
Sparker.
9) Disconnect the valve wires from the DC
Sparker.
10) Unplug the 2 connectors from the valve.
DC Sparker Wires
4) Remove the logs.
5) Remove brick panels, if installed.
6) Remove the valve shield by undoing the 2
screws.
Valve Shield
Spring Hook
Top Mounting Bracket