Regency L234-LP Indoor Fireplace User Manual


 
Regency
®
L234 Direct Vent Gas Insert 31
MAINTENANCE
MAINTENANCE
2) Remove the Termination Cap, and shine a
fl ashlight down the Vent. Remove any bird
nests, or other foreign material.
3) Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints. Continuous condensation can
cause corrosion of caps, pipe, and fi ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.
4) Inspect joints to verify that no pipe
sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
NOTE: Improper positioning of logs may
create carbon build-up and will alter the unit’s
performance which is not covered under
warranty.
GLASS GASKET
If the glass gasket requires replacement use
a tadpole gasket for the Flush Front (Part #
936-155).
Top view of pilot fl ame
Top View of pilot fl ame
Incorrect fl ame pattern will have small, probably
yellow fl ames, not coming into proper contact with
the rear of the burner or thermopile.
Never operate the appliance without the
glass properly secured in place or with
the door open.
7) Do not use this appliance if any part has been
under water. Immediately call a qualifi ed
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.
8) Periodically check the pilot fl ames. Correct
fl ame pattern has three strong blue fl ames: 1
fl owing around the thermopile and 1 around
the thermocouple, and 1 fl owing across the
front of the burner.
Note: If you have an incorrect fl ame pattern,
contact your FPI dealer for further
instructions.
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation and fog is normal and will
disappear in a few minutes as the glass heats
up.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY
AWAY TO AVOID BURNS OR CLOTHING
IGNITION. YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CAUTION: ANY SAFETY SCREEN OR
GUARD REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
MAINTENANCE
INSTRUCTIONS
1) Always turn the gas valve to the off position
before cleaning. For relighting, refer to
lighting instructions. Keep the burner and
control compartment clean by brushing and
vacuuming at least once a year.
When cleaning the logs, use a clean soft
paint brush as the logs are fragile and easily
damaged.
2) Clean (never when unit is hot) appliance,
door and louvers with a damp cloth. Never
use an abrasive cleaner. The fi nishes on
louvers and doors may be scratched if
abrasives are used to clean them. The
heater is fi nished in a heat resistant paint
and should only be refi nished with heat
resistant paint (not with wall paint). FPI uses
StoveBrite Paint - Metallic Black #6309.
3) Make a periodic check of the burner for
proper position and condition. Visually
check the fl ame of the burner periodically,
making sure the fl ames are steady: not
lifting or fl oating. If there is a problem, call
a qualifi ed service person.
4) The appliance and venting system must be
inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed and cleaned from the
burner tray.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other fl ammable vapours and liquids.
Front Burner Tube
Front Burner Tube
DOOR GLASS
Your FPI insert is supplied with high temperature,
5 mm Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. Do
not abuse the glass by striking the surface or by
slamming the door shut.
If your glass requires cleaning, we recommend
using an approved glass cleaner available at
all authorized dealers. Do not use abrasive
materials. Do not clean the glass when hot.
In the event that you break your glass by
impact, purchase your replacement from an
authorized FPI dealer only, do not use substitute
materials. Follow our step-by-step instructions
for replacement. Warning: Wear gloves when
removing damaged or broken glass.
Caution: Do not operate appliance with
glass panels removed, cracked or broken.
Replacement of the glass should be done by
a licensed or qualifi ed service person.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks, and
in extreme cases, holes. These components
should be replaced immediately.