Regency L234-LP Indoor Fireplace User Manual


 
Regency
®
L234 Direct Vent Gas Insert
32
MAINTENANCE
MAINTENANCE
FAN REPLACEMENT
1) Unplug the power source.
2) Open the left and right side faceplate
panels.
3) Remove the bottom louver by pulling out.
4) Remove the glass door.
a) Pull off the left side spring hook that holds
the door in place. While holding the hook turn
it upside down and place it into the middle
opening on the top side mounting bracket.
Repeat for right side
.
b) Swing the door out 45 degrees and lift up
and out.
5) Remove the logs.
6) Remove brick panels, if installed.
7) Remove the burner by undoing the 3
screws.
8) Remove the burner tray by undoing the 4
screws.
Burner Removed
Burner Tray Removed
9) Remove the rear log tray by undoing the 3
screws.
Rear Log Tray Removed
Spring Hook
Top Mounting Bracket