Regency L234-LP Indoor Fireplace User Manual


 
Regency
®
L234 Direct Vent Gas Insert 15
INSTALLATION
INSTALLATION
9) Remove burner orifi ce with a 1/2" wrench
and discard.
10) Install the new LP burner orifi ce stamped
#54 and tighten.
11) Pull off the pilot cap to expose the pilot
orifi ce.
12) Unscrew the pilot orifi ce with the supplied
allen key and replace it with the LP pilot orifi ce
in the kit and re-install the pilot cap.
13) From the valve remove the black protec-
tion cap by hand from the high-low knob
(Fig.1).
Fig.1
14) Insert the allen key
into the hexagonal
key-way of the screw
(Fig. 2), rotate it
counter-clockwise
until it is free and
extract it.
Fig.2
15) Check that the screw is clean and if
necessary remove dirt.
16) Flip the screw (Fig. 3).
17) Using the allen key as shown in Fig.4,
rotate the screw clockwise until snug, do
not overtighten.
Fig.3
Fig.4
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
18) Verify that if the conversion is from NG to
LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
20) Attach the label "This unit has been con-
verted to Propane" near or on top of the
serial # decal.
21) Replace yellow "Natural Gas" label with red
"LPG" label.
22) Reverse steps 8) to 1).
NOTE: Before re-installing the burner,
check the LP areation settings.
23) Check the inlet and outlet pressures.
24) Check operation of fl ame control.
25) Check for proper fl ame appearance.
19) Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and main
burner injectors
are appropriate for the gas type.
Fig.6