G36D Zero Clearance Direct Vent Gas Fireplace
®
G36D Zero Clearance Direct Vent Gas Fireplace
®
4
This is a copy of the label that accompanies
each G36D Zero Clearance Direct Vent Gas
Fireplace. We have printed a copy of the
contents here for your review. The safety label
is located on the front inside base of the unit,
visible when the bottom louver is open.
NOTE:
UltraGlow
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
SAFETY LABEL
Copy of Safety Decal for G36D-NG1
APPAREIL FONCTIONNANT AU GAZ PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation
minimum
Pression à la tubulure d' chappement lev
e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
l'altitude
Modéle
G36D-LP1
é é
é
é
é
é
Calorifique
Calorifique
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
300
NATURAL GAS:
Minimum supply pressure
Manifold pressure high
Manifold pressure
low
Orifice s
ize
Minimum input
Maximum input
Altitude
Model G36D-NG1
L
PROPANE:
Minimum supply pressure
Manifold pressure high
Manifold pressure
low
Orifice s
ize
Minimum input
Maximum input
Altitude
Model G36D-LP1
L
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd.
Delta,
BC, Canada
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from
:
Mantel Clearances from
Top:
Side
Wall Clearance
from Side Facing
Alcove Clearances:
Minimum
Vent Clearances:
Top, sides, bottom and rear of unit
(A) Min. 7" (177mm
)
B) 6"
with Flush
Alcove approved for
Flush Louvers.
Max. Depth 36"(914mm)
Min. Widt
h 48" (1219mm),
Min. Height 72"(1229mm)
Horizontal To
p 2-1/2" (64mm)
Horizontal Side
Horizontal Bottom 1-1/2" (38mm
)
1-1/2" (38mm
)
Serial No./ No de serie
918-493
5" WC(1.25 kPa)
3.8" WC(0.95 kPa)
1.1" WC(0.27 kPa)
# 4
2 DMS
13,100 Btu/h (4.54 kW)
0-4500 ft/pi(0-1372 m)
26,000 B (8.79 )tu/h kW
12" WC(3.00 kPa)
11" W
C(2.74 kPa)
2.9" WC(0.72 kPa)
# 5
3 DMS
13,800 Btu/h (3.96 kW)
0-4500 ft/pi(0-1372 m)
26,000 B (7.91 )tu/h kW
APPAREIL FONCTIONNANT AU NATURAL GAZ
CONCU POUR ETRE POELE:
Pression d'allimentation
minimum
Pression à la tubulure d'
chappement lev e
Pression à la tubulure d'
chappement basse
Grandeur de l'injecteur
D bit minimum selon
D bit maximum selon
l'altitude
Modéle
G36D-NG1
é é é
é
é
é
Calorifique
Calorifique
VENTING:This appliancemustbe installedinaccordance withthe manufacturer'sinstallationinstructions andwith local
codes, if any; if not,follow the currentANSI Z223.1 in the USAor the currentCAN 1-B149 in Canada. For Manufactured
Home
Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's
installation instructions
and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the
currentStandardforFireSafety CriteriaforManufacturedHomeInstallations,Sites,and CommunitiesANSI/NFPA501A,
and with CAN/CSA Z240 MH Mobile Home Standard in Canada. This appliance is only for use with the type of gas
indicated
on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home
where
not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for usewith other
gases,unlessacertifiedkitisused.
Not for use
with solid fuel.
This vented gas fireplace is not for use with filters.
MAY BE INSTALLED IN MANUFACTURED (MOBILE)
HOMES AFTER FIRST SAL
E.
Listed:
Certified for/Certifi e pour:
Tested to:
Report No.
VENTED GAS FIREPLACE HEATER
CANADA and U.S.A.
Gas-Fired Appliances For Use At High Altitudes
476-3031-977
é
CAN/CGA-2.17-M91,
Vented Gas Fireplace Heaters ANSI Z21.88b-2003/CSA2.33b-2003
Made in Canada/Fabrique au Canada
Duplicate S/N
B
B
32"
Ceilin
g
Wall
Wall
A
(See Instruction Manual for
Detailed Instructions)
Model/M
odele:
G36D-NG1
Model/Modele:
G36D-LP1
300
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the
appliances individual manual shut-off must
be a t-handle type valve.