RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS
UltraGlow
®
UltraGlow
®
UltraGlow
DIRECT VENT SYSTEM (FLEX)
®
DIRECT VENT SYSTEM (FLEX)
®
(Propane & Natural Gas)
The diagram shows all allowable combinations of vertical runs with horizontal terminations,
using one 90
using one 90
o
elbow
(two 45
o
elbows equal one 90
o
elbow).
Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid vent systems.
All Rigid Pipe Systems
All Rigid Pipe Systems
4" inner diameter
6-5/8" outer diameter
UltraGlow
UltraGlow
®
UltraGlow
®
UltraGlow
Flex Vent
®
Flex Vent
®
4" inner diameter
6-7/8" inner diameter
Maintain clearances to combustibles as listed
in the "Cl
earances," "Mantel Leg Clearances," "Framing and Finishing
," & "Combustible
Ma
ntel
s
" section
s.
Horizontal vent must be supported every 3 feet.
Firestops are required at each fl oor level and whenever passing through a wall.
A vent guard should be used
whenever the termination is lower
than the specifi ed minimum or as
per local codes.
Note: UltraGlow
®
Direct Vent System
®
Direct Vent System
®
(Flex) is only approved for
horizontal terminations.