UltraGlow
®
G36D Zero Clearance Direct Vent Gas Fireplace
®
G36D Zero Clearance Direct Vent Gas Fireplace
®
26
28)
Install
the
1/2"
bushing
to
the
heat
shield.
30
)
Plug the DC spark generator wires to the
DC Sparker
.
31
)
Connect the ground wire to the DC
Sparker mounting bracket.
32
)
Mount the heat shield to the DC Sparker
.
Secure into place with the velcro, which
is provided in the kit.
Heat Shield
29)
Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
34)
T
ie up the loose wire with the wire clip.
Chain
33
)
F
ind a location which is not too hot and
is easy to reach for changing the batter
y.
Note:
It should be kept away from the
chain.
35)
Check for gas leaks.
36
)
Check inlet and outlet pressures.
37)
Check operation of
fl
ame control.
38
)
Check for proper
fl
ame appearance and
glow on logs.