Note 1: In residential installations, when using parts #811-0860, (3" - 3" Top Vent Adapter) and #812-3570 (3" - 6" Offset Adapter), 24
gauge 6" single wall flue connector may be used.
Note 2: In manufactured home installation, when using part #811-0860, (3" - 3" Top Vent Adapter) and #812-3570 (3' - 6" Offset
Adapter), use listed double wall flue connector. An Outside Air Kit (#811-0871), must be used with manufactured home installation.
A
B
C
D
E
F
C
F
2000 2001 2002 JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC
OMNI-Test Labs, Inc.
Beaverton, OR
Report No. 061-S-20-2
Model:
QUADRA-FIRE CONTOUR
Serial No.
O-T L
Tested and
Listed by
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc.
C
Room Heater Pellet Fuel BurningType
Also for use in Mobile Homes. This pellet burning appliance has been tested and listed
for use in Manufactured Homes in accordance with
OAR 814-23-900 through 814-23-909
1445 North Highway
Colville, WA 99114
'PREVENT HOUSE FIRES"
Install and use only in accordance with manufacturer's
installation and operating instructions. Contact Local
Building or Fire Officials About Restrictions and
Inspection in Your Area.
WARNING - FOR MANUFACTURED HOMES: Do not install
appliance in a sleeping room. An outside combustion air
inlet must be provided. The structural integrity of the
manufactured home floor, ceiling and walls must be
maintained.
Refer to manufacturer's instructions and local codes for
precautions required for passing chimney through a
combustible wall or ceiling. Inspect and clean exhaust
venting system frequently in accordance with
manufacturer's instructions.
Use a 3" or 4" diameter type "L" or "PL" venting system.
Do not connect this unit to a chimney flue servicing
another appliance.
Tested to:
ASTM E 1509, and ULC-C1482-M1990 Room Heater
Pellet Fuel Burning type (UM) 84-HUD
Input Rating Max 4 lb. fuel/hr.
Electrical Rating: 115 VAC, 60 Hz,
Start 4.1 Amps, Run 1.1 AMPS.
Route power cord away from unit
DANGER: Risk of electrical shock. Disconnect power
supply before servicing.
Replace glass only with 5mm ceramic available from
your dealer
To start, set thermostat above room temperature, the
stove will light automatically. To shutdown, set
thermostat to below room temperature. For further
instruction refer to owner's manual.
Keep viewing and ash removal doors tightly closed
during operation.
Minimum Clearances to Combustible Materials
U.S. ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].
Date of Manufacture
DO NOT REMOVE THIS LABEL MADE IN U.S.A.
Use a non-combustible floor protector extending under
unit and to the sides, front and back of unit as shown
in Floor Protection Diagram. Measure front distance
(I) from the surface of the glass door.
*Exceptions: Non-combustible floor protection must
extend beneath the fluepipe when installed with
horizontal venting or under the top vent adapter with
vertical installation.
A Back Wall to Appliance 2"/5cm
B Side Wall to Appliance 6"/15cm
Corner Installation:
C Walls to Appliance 2"/5cm
Vertical 3" - 6" Adapter Kit (Part #812-3570) Installation:
D Back Wall to Appliance Flue 3"/8cm
E Side Wall to Appliance 6"/15cm
Corner Installation with Vertical Adapter Kit:
F Walls to Appliance 2"/5cm
Alcove Installation:
Min. Alcove Height: 43"/1092cm
Min. Alcove Side Wall 6"/15cm
Max. Alcove Depth 36"/91cm
FOR USE WITH PELLETIZED WOOD FUELOR SHELLED FIELD CORN ONLY.
G
G
I
G = 2"/5cm
H = 2"/5cm *See Exceptions Below
I = 6"/15cm
*H
FLOOR PROTECTION
October 10, 2001 4 250-5583
Contour Pellet Stove
SAFETY LABEL
LABEL LOCATION: BEHIND LEFT SIDE CURTAIN ON OUTSIDE OF HOPPER