Mt. Vernon Pellet Stove (AE)
E. Bafe Removal
a. The appliance must be in complete shutdown, com-
pletely cool and the exhaust blower off.
b. Open door.
c. The bafe is located at the top inside of rebox.
d. Remove bafe by placing a at head screw driver into
the slot of the latches located in the upper corners and
push down. The bottom of the latch will fall forward off
of the post. Lift the bafe up and then out toward you.
Figure 39.2.
e. To replace the bafe, place the  locating ears behind
the bottom edge and tilt the bafe up and into place.
f. The bafe must be centered in the rebox before latch-
ing it in place. If it is not centered the latch is trapped
between the bafe and side of the rebox instead of
latching properly.
g. The bottom of the latches will t over the posts. Push
the top of the latch forward to lock latch into place.
WARNING
Cast iron is a very heavy material. The bafe is
made of cast iron and therefore is heavy and awk-
ward at times to maneuver. Clear and prepare
your work area before you begin.
Baffle
Latches
Insert flat head screw driver into “V”
section and push down and the bottom
of the latch will fall forward off of post
Locating ears - 1 on
each side. Fit behind
bottom edge.
Figure 39.2
Pellets Back-Up
in Feed Tube
Firepot Overfills
Ash Build-Up in Firebox
Figure 39.1
D. High Ash Fuel Content Maintenance
Frequency: When the ash build-up exceeds the half
way point in the repot
By: Homeowner
If the ash build-up exceeds the half way point in the repot
before it automatically cleans, then the repot is not being
cleaned often enough.
Another symptom is if clinkers are adhering to the sides of
the repot.
Double check the wall control to ensure the proper setting
has been selected for the fuel you are burning. If that is cor-
rect, change the setting to “Utility Pellet”.
NOTE: You will need to empty the ash pan more fre-
quently if using the “Utility Pellet” setting.
WARNING! Risk of Fire and Smoke!
• Highashfuelsorlackofmaintenancecancauserepotto
overll.Followpropershutdownprocedureifashbuildup
exceedshalfwaypointinrepot.
• Failure to do so could result in smoking, sooting and pos-
siblehopperres.