Quadra-Fire MTVERNON-AE-MBK Stove User Manual


 
R
R
R
August 13, 2009
7034-106F
Page 5
Mt. Vernon Pellet Stove (AE)
3. Automatic or Manual Setting
The automatic setting will control the heat output based on
the comfort level selection. The manual setting allows you
to manually control the heat output settings. See page 27,
Ignition Cycles.
NOTE: See the Wall Control Thermostat manual for
detailed instructions.
E. Before Your First Fire
First, make sure your appliance has been properly installed
and that all safety requirements have been met.
Pay particular attention to the re protection, venting and
thermostat wall control installation instructions.
Double check that the ash pan, hopper and rebox are
empty and then close the rebox door.
NOTICE:
The tip of thermocouple must be in contact with the
inside end of the thermocouple cover or missed ignitions can
occur.
F. Filling the Hopper with Fuel
G. Starting Your First Fire
1. Fuel Selection
To start your rst re, you must:
Select the appropriate fuel on the FUEL SELECTION screen
on the thermostat wall control to match the fuel you have
chosen to burn.
If
the proper fuel is not selected your appliance will not
operate properly.
For example, if
you have selected wood pellets and you are
burning corn, the appliance may not light, it may go out or
overfeed. Figure 25.1.
NOTE: If you are lighting your appliance for the rst time:
The feed tube
will be empty and it can take some time to ll
it with fuel before you will see a re
Put a handful
of fuel in the repot (priming) to speed up the
process. You can also do this when you have run com-
pletely out of fuel.
Sunflower Seeds
Corn
Utility Pellet
Softwood Pellet
Wheat
Hardwood Pellet
DONE
SELECT
FUEL SELECTION
2. Comfort Level Selection
Once your fuel is selected, select the temperature at the desired
setting on the SET COMFORT LEVEL screen. Figure 10.2.
Figure 25.2
Figure 25.1
Check the hopper and make sure it is empty before lling
with fuel.
Open the cast top hopper lid.
Do not over ll the hopper. The hopper lid must be com
-
pletely closed to maintain proper vacuum and for the feed
motor to operate. An error ICON will appear on the wall
control if the hopper lid is not properly closed.
Do not leave
any part of the fuel bag on the appliance after
lling hopper.
H. Fire Characteristics and Flame Height
(Feed Rate) Adjustment
A properly adjusted re will have an active ame pattern and
the ame will rise and fall somewhat. This is normal.
On HIGH setting, the ame will extend approximately 8
inches (0mm) out of the repot. If it is not 8 inches
(0mm) tall, increase the ame height.
On MEDIUM or LOW setting the ame will be shorter.
Reduce the ame height i
f the re has tall ames with
black tails and seems somewhat lazy. This may also
indicate that the repot and/or heat exchanger needs to
be cleaned. Refer to Section 10 for Maintenance and
Cleaning Instructions.
Adjusting the Flame Height (Feed Rate)
Set your appliance to “MANUAL” mode on the wall con-
trol.
Set the heat output level to HIGH.
Adjust the ame height using the “FLAME HEIGHT
AD
-
JUST” screen on the wall control. Figure 25.3.
Figure 25.3