Quadra-Fire MTVERNON-AE-MBK Stove User Manual


 
Page 18
7034-106F
August 13, 2009
R
Mt. Vernon Pellet Stove (AE)
R
R
6
Mobile Home Installation
1. An outside air inlet must be provided for the combustion
air and must remain clear of leaves, debris, ice and/or
snow. It must be unrestricted while the appliance is
in use to prevent room air starvation which causes
smoke spillage. Smoke spillage can also set off smoke
alarms.
. The combustion air duct system must be made of
metal. It must permit zero clearance to combustible
construction and prevent material from dropping into
the inlet or into the area beneath the dwelling and
contain a rodent screen.
. The appliance must be secured to the mobile home
structure by bolting it to the oor (using lag bolts).
Use the same holes that secured the appliance to the
shipping pallet.
. The appliance must be grounded with #8 solid copper
grounding wire or equivalent, terminated at each end
with an NEC approved grounding device.
5. Refer to Clearances to Combustibles and oor protec-
tion requirements on page 8 for listings to combustibles
and appropriate chimney systems.
6. Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the the exterior of the structure.
7. Follow the chimney manufacturer’s instructions when
installing the vent system for use in a mobile home.
8. Installation shall be in accordance with the Manufactur-
ers Home & Safety Standard (HUD) CFR 80, Part
24.
NEVER INSTALL IN A SLEEPING ROOM.
WARNING
You must use a Quadra-Fire Outside Air Kit
for installation in a mobile home.
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Approved Class L
or PL Pellet Vent
Figure 18.1
CAUTION
Never draw outside combustion air from:
Wall, oor or ceiling cavity
Enclosed space such as an attic or garage
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL AND CEILING/ROOF MUST BE MAIN-
TAINED
Do NOT cut through:
Floor joist, wall, studs or ceiling trusses.
Any supporting material that would affect the structural
integrity
.