Quadra-Fire MTVERNON-AE-MBK Stove User Manual


 
Page 8
7034-106F
August 13, 2009
R
Mt. Vernon Pellet Stove (AE)
R
R
5. Auto-Clean Cycle
The repot auto-clean system will cycle:
When the appliance is rst plugged in
When the house reaches temperature and the appliance
shuts down
At prescribed intervals, depending on the type of fuel se-
lected
When starting up after an electrical interruption
If your appliance is running and the auto-clean cycle is initi-
ated, the appliance will revert to shutdown cycle.
The oor of the repot will open and dump the ash into
the ash pan
It takes approximately  minutes to complete the auto-
clean cycle
The oor will then shut, and if the thermostat is still call-
ing for heat, the re will start again
During this auto-clean cycle, the convection blower may
continue to run. The combustion blower will continue to
run.
Additional Screen Messages:
READY It is telling you that the home is up to temperature
and doesn’t need any heat.
- - - - - The screen will show 5 dashes when the wall
control and the control board are NOT communicating with
each other. Check that the wiring on the thermostat is prop-
erly connected.
MAINTENANCE BURN This indicates the appliance is
operating on battery backup, prior to the auto-clean. The
maintenance burn will keep the system from shutting down
as the appliance will not automatically re-light in battery
back-up mode.
OFF The AUTO/MANUAL SETTING screen has been set
to OFF. Set the appliance to OFF when performing periodic
maintenance to prevent an unexpected startup.
BLANK SCREEN The ON/OFF switch may be in OFF
position. Turn to ON position.
WARNING
Fire Risk
Do NOT operate appliance:
With appliance door open.
With repot oor open.
Do NOT store fuel:
Closer than required clearances to com-
bustibles to appliance.
Within space required for loading or ash
removal.