Quadra-Fire DV400S Indoor Fireplace User Manual


 
March 4, 2002 Page 8 30211C
DV400S DIRECT VENT ROOM HEATER
R
Figure 1
Minimum Clearances To Combustibles
The following clearances to combustibles must be main-
tained:
Minimum clearances to the floor - 0"
Back of unit to wall - 6”
Sides of unit to wall - 6
Base of the unit to ceiling - 72".
Minimum clearances to Venting are as follows:
Horizontal runs require a 1-1/2” minimum Air Space on the top and
an 1/2” minimum Air Space on the sides and bottom of the outer
Vent Section. If an Elbow is being used,in an enclosed wall, floor
or ceiling, a top Air Space clearance of 3” must be maintained.
Vertical rise sections require a 1” minimum Air Space completely
around the Vent section. These clearances must be maintained
at all times.
This appliance is certified for installation in a bed/sitting room in
the U.S. and Canada.
Mobile Home Installations. Appliances installed in Mobile Homes
must be secured to the floor in a minimum of two locations.
S
T
O
V
E
STOVE
6"
6"
6"
6"
48"
MAX.
4"
4"
STOVE
HEARTH PROTECTION IS NOT
NECESSARY ON THIS GAS HEATER.
Positioning the Appliance.
This appliance may be placed on a combustible or non-combus-
tible continuous, flat surface. When the appliance is installed
directly on carpeting, tile or other combustible material other than
wood flooring, the appliance shall be installed on a metal or wood
panel extending the full width and depth of the appliance. Slide
the Heater into position and level the Heater from side-to-side
and front-to-back. Shim as necessary.
CLEARANCES
DURA-VENT GS VENTING SYSTEM COMPONENTS
CATALOG # DESCRIPTION
953 Storm Collar
963 Firestop Spacer
988 Wall Strap
981 Snorkel Termination (36")
982 Snorkel Termination (14")
971 Horizontal Kit (Horizontal Termination Cap, One 90 Degree Black Elbow, Wall
Thimble, 24" Black Pipe, 11" - 14 5/8" Adjustable Vent
980 Vertical Termination Cap with Wind Halo
984 Horizontal Termination Cap
909B Retrofit Adjustable Chimney Connector Retrofit Chimney Connector Plate
950 VSS - Vinyl Siding Standoff/Shield
3951 Round Ceiling Support/Wall Thimble Trim Kit, Polished Brass
3960 Cathedral Ceiling Support Trim Kit, Polished Brass
HHW2 Horizontal High Wind Cap (recommended for optimal performance)
HHW2K Horizontal Kit (One 90 degree Elbow, Wall Thimble, 24" Black Pipe, 11" - 14 5/8"
Adjustable Vent, HHW2 Termination Cap.