Quadra-Fire DV400S Indoor Fireplace User Manual


 
DV400S DIRECT VENT ROOM HEATER
March 4, 2002 Page 21 30211C
R
OPTIONAL ACCESSORIES
A. Optional Fan
Blower Installation:
1. Remove the Knockout Plate from the Backshield of the
DV400S by prying out on the plate and clip or break the
tabs that hold it in place. See Figure 1 below.
2. Remove the tape from the back of the strip of Gasket
Material included with the blower kit, and position the
Gasket over the edge of the opening of the Backshield.
See Figure 2 below. (This will eliminate vibration.)
3. Install the Blower into the Backshield by hooking the
bottom of the Blower Housing into the opening and rock
the top of the Blower forward. Fasten the blower in place
with the screws included in the Fastener Pack. See Figure
4 on this page.
4. Attach the On/Off Switch Box for blower to the
Backshield with the screws provided. See Figure 3, this
page.
5. Plug the Connector on the wiring assembly into the
Receptacle on the top of the Blower Housing. See Figure
4 this page.
Figure 1
Removal of Knockout Plate
Figure 2
Placing Blower Gasket on Back Shield
Figure 3
Attach On/Off Switch Box for blower
Figure 4
Fan Installation on Backshield also
showing blower Receptacle
The Optional Fan Kit (844-0150) requires a 110VAC supply.
Optional accessories may be added now or at a later date.
Blower
Receptacle
Attach here.