Quadra-Fire DV400S Indoor Fireplace User Manual


 
March 4, 2002 Page 22 30211C
DV400S DIRECT VENT ROOM HEATER
R
WARNING!
Electrical Grounding Instructions
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Blower Wiring Diagram
B. Optional Wall Thermostat
The use of a millivolt Thermostat is allowed. It must be
located within 20 feet of the appliance. In order for the
Thermostat to work, the “ON/OFF” Switch must be in
the “ON” position.
Figure 15 shows how to connect a millivolt Thermostat
without the “ON/OFF” Switch in the Circuit. Disconnect
the “ON/OFF” Switch from the Valve and wire the millivolt
Thermostat as indicated.
20613
(1)
14212 (1)
25385 (1)
25579 (1)
25580 (1)
28749 (1)
18164 (1)
2
3998 (1)
3
2 1
FAN
CONTROL
F
F
F
BLK
BLK
RED
BLK
FM
WHT
C. Remote Control
A remote control thermostat may be installed on this stove.
Contact your dealer for the correct model.
D. Warming Shelves/Brackets
Please see the Installation Instructions included with the
Shelves. Refer to page 7, Heater System Components, for
ordering purposes.
E. Door Trim
Part # 844-0140. Please read the Installation Instructions
included with the Door Trim.
Warming Shelf and Bracket
Decorative Glass Accent
Figure 15 - Wiring Diagram
Fan
Speed
Control
Ignitor
Burner
ON/OFF
switch
Valve
Copper
Pilot
Assembly
Junction Box
Fan Assembly
Convection Air
Temp Switch
Black = B
White =W
Red = R
B
W
W
W
R
R
B
B
B
Gas Pilot
I
g
nit
o
r
Thermo
couple
Thermopile
Thermopile