Quadra-Fire CB1200 Stove User Manual


 
Page 8
7014-082B
September 21, 2006
R
CB 1200 Pellet Stove
R
R
Straight Back Against
Wall
Inches Millimeters
A
Back Wall to Appliance 2 51
B
Side Wall to Appliance 6 152
Corner Installation
Inches Millimeters
C
Walls to Appliance 2 51
Vertical Installation
Inches Millimeters
D
Back Wall to Flue Pipe 76
E
Side Wall to Top 6 152
F
Back Wall to Appliance 7.5 191
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches Millimeters
G
Walls to Appliance 2 51
B. Clearances to Combustibles (UL and ULC)
D
E
F
A
B
Fire Risk.
Comply with all minimum clearances to
combustibles as specied.
WARNING
Failure to comply may cause house re.
NOTE:
Illustrations reect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
C
C
G
G
Alcove Installation
Inches Millimeters
Minimum Alcove Height 44 1117
Minimum Alcove Width 40-1/2 1029
Maximum Alcove Depth 6 915
Minimum Alcove Side Wall 6 152
Top of Unit to Combustibles 12-1/2 18