CB 1200 Pellet Stove
16. Snap Disc #1 (Convection Blower) 145°F
Snap disc #1 is located on the right side of the appliance on
the top of the heat exchanger box. There are 2 purple wires
connected to it. This snap disc turns the convection blower
on and off as needed. Power is always present at snap disc
#1.
17.
Snap Disc #2 (Thermostat Override) 200°F
Snap disc #2 is also located on the right side of the appliance
between snap disc #1 and convection blower. There are 2
yellow wires connected to it. This snap disc will turn off the
feed system, which will turn off the appliance if an overre
condition should occur or if the convection blower should fail
to operate.
18.
Snap Disc #3 (Back Burn Protector) 250°F
Snap disc # is mounted on the back of the auger tube in the
right side of the appliance just below the feed motor and has
a red reset button. To access it remove the feed motor cover
box from inside the hopper. If the re tries to burn back
into the feed system or push exhaust up the feed tube, this
snap disc will shut the entire system off. This disc must be
manually reset.
19. Vacuum Switch
The vacuum switch is located on the left side of the appliance
behind the inner shield. This switch turns the feed system on
when vacuum is present in the rebox. The vacuum switch
is a safety device to shut off the feed motor if the exhaust
or the heat exchanger system is dirty or plugged or if the
rebox door is open.
20. Wiring Harness
See Figure 35.1 below.
Figure 35.1
Thermocouple
Heat
Output
Switch
Thermostat
Block
Snap
Disc #2
Snap
Disc #1
Feed
Motor
Male
Vacuum
Switch
Capacitor
Female
Convection
Blower
Blower
Speed
Exhaust
Blower
Snap
Disc #
Reset
Button
Call Light
Fuse
Yellow
Yellow
Purple
Purple
Red
Red
Orange
White
White
Yellow
Blue
Blue
Blue
Black
Black
Gray
Gray
High Temp
High Temp
Yellow
Igniter