Page 9
32198A February 15, 2002 32198A February 15, 2002
Cape Cod Wood Stove
R
(In inches and millimeters)
FIGURE 4
In a Masonry Fireplace OR Through the Wall: Six inch (6") diameter listed double wall air insulated connector pipe with
listed factory-built Class “A” chimney or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)
Additional specications include a maximum 8" deep mantel without heat shield and the following clearances:
A B C D E F G H I
N/A N/A 27.5"(698) 18"(457) N/A N/A 41"(1041) / 15"**(381) N/A 12" (305),
6"*(152)
CLEARANCES
FIGURE 4
**Maximum 8" deep mantel with heatshield spaced
1" from bottom mantel surface.
*With 52" high x 42" wide wall protection spaced 1"
from combustible surface..
If further clearances are needed, obtain requirements for construction of a protected wall from
your local building code authorities and their allowable reductions of the listed clearances.
WALL PROTECTOR SPECIFICATIONS:
MUST BE A MINIMUM OF 24 GAUGE
SHEET METAL WITH A 1" (25MM) AIR
SPACE BETWEEN SHEET METAL AND
COMBUSTIBLE WALL. SHEET METAL
MAY THEN BE COVERED WITH BRICK
OR TILE.
MINIMUM CLEARANCES TO COMBUSTIBLES
CAUTION!
The baffle and kaowool blanket placement is
crucial to the optimum performance of the Cape
Cod. Follow the steps on pages 32 & 33 (Chimney
Cleaning), carefully to ensure proper placement of
bafes and kaowool at time of initial installation
and following chimney cleaning.
REAR VENT INSTALLATIONS
G
G
I
Max 8"
C
L
26-5/8"