INSTALLATION
CONNECTION TO A MASONRY
FIREPLACE
There are several kits available to connect the stove to a masonry replace. Look for a listed kit. The kit
is an adapter which is installed at the location of the replace damper. The existing damper may have to be
removed to allow installation of the kit. The key points of this type of stove connection are that the connector
pipe must extend up the chimney above where the re clay liner starts, and the areas of the kit installation and
penetration should t tightly and be sealed with high temperature furnace cement unless the kit’s instructions
state otherwise. (See Figure 12). The tight tting installation aids the proper draw of the chimney.
FIGURE 12
6
Support Plate & Clamp
Listed Rigid
Stainless Liner
Stainless Steel
Flex Section
Stainless Connector Pipe
Carry Stovepipe
Above the Liner
Damper Plate is
Removed or
Fastened in Open
Position
Use Damper Adapter or
Seal With Sheetmetal
and Sealant
Cleanout
Stainless Tee with Cleanout
Fireclay liner 5/8"
(16mm) Minimum or
Equivalent.