Quadra-Fire 32198A Stove User Manual


 
Page 11
32198A February 15, 2002 32198A February 15, 2002
Cape Cod Wood Stove
R
The Cape Cod has several options available for installation and appearance. These options are packaged
and sold separately and are listed below.
It is a good idea to plan your installation on paper, using exact measurements for clearances and oor
protection, before actually beginning the installation. If you’re not using an existing chimney, place the stove
where there will be a clear passage for a factory-built listed chimney through the ceiling and roof.
AVOID FIRE: Maintain the designated clearances to combustibles. Insulation must not touch the
chimney. You must maintain the designated air space clearance around the chimney. This space around a
chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat
buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved
by the regulatory authority having jurisdiction.
We also recommend that you have a qualied building inspector and your insurance company representative
review your plans before installation.
ACCESSORIES
831-1700 160 cfm Electric Blower
831-1780 Outside Air Kit
844-7980 Gold Brackets w/mitten rod
844-7970 Black Brackets w/mitten rod
834-3610 Fire Screen (US Installations ONLY)
Warming Shelves
834-3531 Matte Black WS3-2 MBK
834-3551 Porcelain Creme , WS3-2 PCR
834-3561 Porcelain Green, WS3-2 PGR
834-4110 Porcelain Majolica, WS3-2 PMJ
834-4120 Porcelain Blue/Black, WS3-2 PBB
842-3950 Canadian Floor Protector
*Hearth Legs
834-3800 Matte Black, MBK
834-3820 Porcelain Creme, PCR
834-3830 Porcelain Green, PGR
834-4130 Porcelain Majolica, PMJ
834-4140 Porcelain Black/Blue, PBB
*If you install Hearth Legs please note that you can install
an Outside Air Kit or Blower but not both.
Part Number