Quadra-Fire 32198A Stove User Manual


 
Page 10
32198A February 15, 2002 32198A February 15, 2002
Cape Cod Wood Stove
R
CLEARANCES
FIGURE 5A
NOTE: Additional oor protection is required on
rear vent installations. For this type of installation the
oor protector must extend the length of the ue and 2"
to each side of the ue. Floor protection can consist of
a U.L. Listed oor protector, or the site fabricated hearth
protector described below.
(Thermal Conductivity) “k” = BTU in./hr. ft
2
F (based
on 1" thickness)
To substitute alternate insulation material, you need
to know the “k” factor for that material. To calculate
the required thickness for the alternate material use the
following formula:
“k” of Alternate material
x .50 = Thickness of alternate-
.45 material (inches)
EXAMPLE: The “k” value of brick = 5
5 x .50 = 5.5 inches of brick is
.45 required to meet the
requirement.
FIGURE 5C
The oor must be non-combustible or otherwise
adequately protected from radiant heat given off by
the unit and from sparks and falling embers. A layer
of thin brick or ceramic tile over a combustible oor
is not sufcient.
In US installations, it is necessary to install a oor
protector of 1" (k value = .45) thick metal clad millboard
or equivalent at least 16" in front and 8" to both sides of
the loading door. See Figures 5A & 5C.
In Canada, similar floor protection must be
provided 18" in front and 8" from the sides and rear of
the stove. See Figures 5B & 5C.
FLOOR PROTECTION
USA MINIMUM FLOOR PROTECTOR:
36-3/4" WIDE x 39-1/4" DEEP
If Hearth Leg kit is used in rear vent installation,
Floor Protector must extend 18” in front of the
fuel loading door.
CANADIAN MINIMUM FLOOR PROTECTOR:
32-1/2" WIDE x 49-1/4” DEEP
ADDITIONAL FLOOR PROTECTOR REQUIREMENT:
Part #842-3950, provided with stove, must be placed beneath
ash catcher extending lengthwise towards front of stove.
Required
Thickness “k” Value
MICORE 300 1" .45
Non-combustible decorative
covering or .018 min. sheet metal.
Insulation min. R value 2.2
FIGURE 5B
16" from glass
8"
USA
Fuel loading door
5-13/16
2-3/16
36-3/4
39-1/4
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1251mm
(49-1/4")
1080mm (32-1/2")