Pelco C3468M Home Security System User Manual


 
28 C3468M (4/10)
Switch Settings
WARNING: If you are using Pelco D-type or Pelco P-type control, your system may not operate if
the baud rate and address switches are not set correctly. The switches are set at the factory using
the defaults for Pelco D-type control (2400 baud and address 1).
Table D. Switch Settings for SW2
Special Systems
Switch Number 12345678910
AD-32 Preset System ON
CM9502 Setting ON
Vicon
Not currently available; SW2-3 is reserved for future use.
Serial Port Settings
Switch Number 12345678910
RS422 OFF OFF
RS485, 4-Wire OFF ON
RS485, 2-Wire ON ON
Pelco D or Pelco P Protocol Baud Rate
Switch Number 12345678910
2400 Baud
(Default for D-type Control)
OFF OFF OFF
4800 Baud
(Default for P-type Control)
ON OFF OFF
9600 Baud OFF ON OFF
Video Cable Type
Switch Number 12345678910
Coaxial Cable OFF
Dome Termination
Switch Number 12345678910
Terminated ON
Not Terminated OFF