L NAPCO Security Systems
Freedom F-64 Installation Instructions
WI1501A 9/06
Page 19
Arm if not closed at end of window. When the start time is reached, the display will notify the occupants that an Auto-Arm will be initiated
in the notification period length of time. After that period has expired, a 15 minute period will count down to Auto-Arm with the sounder
pulsing. Auto-Arming may be canceled by arming and then disarming the panel. An Auto-Arm will be reported as User 33. Auto Arming
can be delayed from 1 to 4 hours by pressing
R button during the 15 minute Auto Arm Period until "TO DELAY AUTO ARM" is
displayed and press the number of hours to delay followed by the
U button.
Auto Output Test on Arming
If selected, this will activate the Burglary Output (on terminals 3 and 4) briefly 10 seconds after the area is armed. If the alarm does not
sound, the device may be defective.
Auto-Bypass (Do not program for UL installations); Auto-Bypass Re-entry
Zones programmed for "Auto-Bypass" will be bypassed (automatically removed) if in trouble when arming. A momentary beep will
sound at the Touchpad/keypad to warn that the system has been armed without the protection of the auto-bypassed zone. (Note that
the exit/entry door should not be used for Auto-Bypass, otherwise the Exit/Entry Zone will be auto-bypassed). Note: A zone in trouble
that is not programmed for "Auto-Bypass" will cause an alarm on arming after a 10-second arming delay.
If "Auto-Bypass Re-entry" is selected, securing a zone that is programmed for Auto-Bypass, while armed, will cause that zone to re-enter
the system in an armed state.
Auto Interior Bypass/Easy Exit (STAY MODE) See Interior Stay Zones
Auto-Reset; Auto-Reset After Burglary Output Timeout (Do not program for UL installations)
If a zone detects an alarm condition and is selected for "Auto-Reset", it will automatically rearm itself as soon as the alarm condition is
cleared. Auto-Reset may be delayed to occur after the Alarm Output timeout period by selecting "Auto-Reset After Burglary Output
Timeout" and "Auto-Reset" . Zones that are not programmed for "Auto-Reset" will not be capable of signaling another alarm until (a) the
cause of the alarm has been corrected and (b) the control panel is disarmed. Also see Swinger Shutdown.
Auto Status Disable
For high security Installations, the automatic scrolling of Zone Faults can be disabled. When any zone is faulted, the display will read,
"Zone Faulted".
Backup Report on Telco 1/Telco 2
If "Backup Reporting on Telco 1/Telco 2" is selected and the communicator does not reach the first telephone number (Telco 1) after
three attempts, seven attempts will be made to reach the second telephone number (Telco 2). Enter Subscriber Identification Numbers
for Telephone 2 and other information required for Telephone 2. Also program Backup Reporting on Telco 2. Any zone programmed to
report to Telco 1 will backup report to Telco 2. Note: Subscriber Identification Numbers for both Telephones 1 and 2 must be entered,
even if they are the same. Any restore will also first transmit to Telco 1 then Telco 2. The alarm and restore may not be transmitted to
the same telco telephone number.
Battery
12VDC standby power source in the control panel is used to provide backup protection in the event of a power loss. The battery is an
integral part of the system and must be installed, even if AC power is present. Change the battery every 5 years or as required.
Burglary Output See Alarm Outputs
Call Waiting See Disable Call Waiting
Callback-Method Download; Disable Second Call Answering Machine Override (MUST program for UL installations); Disable
Callback Download (MUST program for UL installations); Callback Telephone Numbers; Disable Keypad Function Mode
Download; Answer on Ring Number
Data may be downloaded remotely to the panel after a programmed number of rings (3 to 15) and a control-panel confirmation callback.
Program the "Number of Rings"; if not programmed, the panel will pick up after 15 rings.
The feature "2nd Call Answering Machine Override" allows downloading after (1) the panel detects 1 or 2 rings; (2) the panel does not
detect another ring for 8 seconds; (3) the panel detects another ring within the next 22 seconds. At this point, the panel will connect and
allow the panel to communicate with the downloading computer. In this way, the panel overrides the answering machine. The
answering machine will pick up on its programmed number of rings, as usual. Note: The number of rings programmed into the panel
must exceed that of the answering machine.
Program "Disable Callback Download" to prevent unauthorized downloading to an unattended panel. Program "Disable Answering
Machine Download" to inhibit downloading to a telephone connected to an answering machine. Program "Disable Function-Mode
Download" to prevent downloading at the keypad or Touchpad.
Cancel; Cancel Code; Cancel Report to Telco 3; Cancel Window Duration (Report Cancel Window)
CANCEL is the preventing of a report from being sent by entering a user disarm code or I-FOB. If the area is disarmed during Entry De-
Glossary