Mitsubishi Electronics PAC-YT34STA Air Conditioner User Manual


 
13
GB
4-4-1. Setting the program
(1) Open the PROGRAM SETTING screen.
Press the
MONITOR/SET
switch on the PROGRAM MONITOR screen. ("PROGRAM" will
flicker at the upper left when this screen is
opened.)
If no operations are made on this screen for
ten minutes, the display will switch to the
Normal screen.
(2) Set the pattern No. displayed at the pattern
No. display will change as shown on the right
each time the
PATTERN
switch is pressed.
(3) Set the operation No.
The operation No. displayed at the operation No. display will change as shown on the right
each time the
OPERATION
switch is pressed.
(4) Set the operation time.
1. The clock will advance by five minutes when the CLOCK switch is pressed once. When the switch is
held down, the time will advance in five-minute increments or sixty-minute increments.
2. The clock will return by five minutes when the CLOCK
switch is pressed once. When the switch is
held down, the time will return in five-minute increments or sixty-minute increments.
4-4-2. Setting the operation details
Set the details to be operated at the time set in the previous section.
Display only the details to be set.
(1) Set ON/OFF.
The state will change as shown on the right each time the
ON/OFF
switch is pressed.
Set to "No display" if this setting is not required.
(2) Set the operation mode.
The mode will change as shown on the right each time
the
MODE
switch is pressed.
Set to "No display" if this setting is not required.
(3) Set the temperature.
1. The temperature will change as shown below each time the TEMP.
switch is pressed. The
temperature will change continuously in 1 increments when the switch is held down.
19 20 28
2. The temperature will change as shown below each time the TEMP.
switch is pressed. The
temperature will change continuously in 1 increments when the switch is held down.
28 27 19
(4) Set operation prohibit.
The DIP switches must be set to prohibit operations following the schedule with this controller.
Refer to section 8. Setting the functions.
1. Set whether to prohibit or enable operations with the local remote controller.
The state will change as shown below each time the
PROHIBIT
switch is pressed.
(flickers)No display (ON)
PROH.
PROH.
PERMIT
To not set : Leave the display at "No display".
To set prohibit : Set to “
“ (flicker) and set the prohibited item.
To enable : Set to “
“ (lit) All items will be permitted when set to “ “.
(This operation is invalid if the SW3 "operation prohibit" is set to "Invalid". (Always a no display state.)
When
is displayed, the prohibited "ON/OFF", "MODE" and "TEMP." items will display.)
123 9
01 02
03 16
No display
ON
OFF
No display
[COOL] [HEAT]