LOREX Technology L19lD1616501 Home Security System User Manual


 
36
Configuration
When the window is at the ALL OFF mode,
you can activate the motion detection in the
block.
5.BLOCK OFF: Block an area to deactivate
the motion detection in the desired area. The
setup steps are the same as BLOCK ON. If
the window is at the ALL ON mode, you can
deactivate the motion detection in the block
you make.
Interval setup
SWITCH INTERVAL: FULL- Full Screen
Sequence Interval setup. (Range: 1~99
SEC)
PIP- Picture in Picture, the sub-picture's
sequence interval setup. (Range: 1~99
SEC)
2.[EVENT RECORD]
The Event Update Time prevents the DVR
from recording the event logs from the same
event. The event types include alarm,
motion and video loss.
When an event is triggered, it is possible
that the same event will continue to be
triggered for a period of time. With the help
of Event Update Time, whenever there is an
event, the DVR records the starting time and
information of the event in the Event Log,
and ignores the following events within the
duration set in the Event update time. The
setting range of the Event Update time is
from 10 seconds to 990 seconds.
Alarm setup
1. CHANNEL - Use [+] and [-] to select a
channel.
2.ALARM INPUT- Set up the Alarm Input
type.
• N.C- when the alarm is triggered, the
circuit turns closed (ON).
• N.O- when the alarm is triggered, the
circuit turns opened (OFF).
3.DURATION - Set up a post- alarm
recording duration and the alarm output
duration. The duration setting is applied to
both functions. The setting range is from 1
second to 300 seconds.
NOTE: Alarm output can be triggered by
alarm input. Motion and video loss cannot
trigger an alarm output.
Event Popup Setup