Lennox Hearth CI2500DVF Indoor Fireplace User Manual


 
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Top View / Corner Clearances
Top View / Rear Wall or Alcove Clearances
Side View / Rear Wall or Alcove Clearances
Clearance To Combustibles and Alcove Dimensions
Figure 2C
Clearances To Combustible Materials / Floor Protection
• The location should also be free of electrical, plumbing or other
heating/air conditioning ducting.
• Due to high temperatures, this appliance should be located out
of traffic and away from furniture, draperies and not in windy or
drafty areas.
• This appliance can be installed in most residential room configura
-
tions, parallel to a rear or adjacent wall, or in an alcove that allows
for the minimum clearances to combustible surfaces. Your local
building inspector should review your plans prior to installation.
• When installing this appliance, provide adequate clearances for
the purposes of servicing and proper operation.
• As determined through the safety certification of this unit, a minimum
clearance to combustible materials must be maintained around
specific areas of the gas appliance. (See Table 5 and Figures 2A,
2B and 2C).
Clearances
CI1500DVF CI2500DVF
A (minimum) *10” (254 mm) *10” (254 mm)
B (minimum) *14-1/4” (362 mm) *17-1/4” (438 mm)
C (minimum) *15-7/8” (403 mm) *19” (483 mm)
D (minimum) 4”(102 mm) 4”(102 mm)
E (minimum) 2” (51 mm) 2” (51 mm)
F (minimum) 4” (102 mm) 4” (102 mm)
G (minimum) 0” (0 mm) 0” (0 mm)
H (minimum) ***62” (1575 mm) ***62” (1575 mm)
I (minimum) **28-1/2” (724 mm) **34-1/2” (876 mm)
J (MAXIMUM) 48” (1219 mm) 48” (1219 mm)
Table 5
* Dimensions with a single asterix are reference dimensions only.
** If the optional warming shelves are installed, a greater alcove width is
required as follows:
CI1500DVF - 44" (1118 mm) min.
CI2500DVF - 52-1/2" (1334 mm) min.
***This includes any projections such as shelves, windowsills, mantels, etc.
above the appliance.
Note: Recommended clearance zone from the front of the appliance to combus-
tibles is 36 inches (914 mm) minimum.
Floor Protection
When installed directly on carpeting, tile (see Note below) or other
combustible material other than wood flooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the stove body.
Note: Ceramic tile is non-combustible and does not require a wood
or metal panel under the appliance.
Vent Clearances - All Models
For Horizontal Sections: .................At Wall Firestops:
Top - 3" (76.2 mm) min. ............
Top - 3" (76.2 mm) min.
Sides - 1" (25.4 mm) min. .........
Sides - 1" (25.4 mm) min.
Bottom - 1" (25.4 mm) min. .......
Bottom - 1/2" (12.7 mm) min.
For Vertical Sections:
Sides - 1" (25.4 mm) min.
Figure 2B
Figure 2A
H
D
*A
G
J
L E N N O X
*B
D
EE
I
F
F
*C
MINIMUM CLEARANCES TO COMBUSTIBLES