RATING LABELS
MANUFACTURED AT: AUBURN, WASHINGTON
FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)
0-4500 FT (0-1370 M)
4.5”
3.5”
#37
28,000
17,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINIMUM SIDEWALLS
FLOOR
2”
0”
CLEARANCES TO CEILING OR ALCOVE HEIGHT
BACK/CORNER 45q
62”
4”
COMBUSTIBLE
MATERIAL
VENT SURFACES: TOP
SIDES
BOTTOM
3”
1”
1”
ALCOVE MAXIMUM DEPTH 48”
DEGAGEMENT MUR ADJACENTS
PLANCHER
50.8mm
0mm
MINIMUM DE PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
1574.8mm
101.6mm
MATERIAUX
COMBUSTIBLES
SURFACES D’AERATION: DESSUS
COTES
BAS
76.2mm
25.4mm
25.4mm
PROFONDEUR D'ALCÔVE MAXIMALE 1219.2mm
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION:
Do not operate the appliance with glass removed, cracked or broken.
Replacement of panel should be done by a licensed or qualified service person.”
“This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N H3705”
INAL INSPECTION BY:
ANSI Z21.88-2007
CSA 2.33-2007
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N 9-1452A
SERIAL NUMBER/NOMBRE DE SERIE
XXXXX XXXXX
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
P/N 9-1452A
DO NOT SCALE THIS PRINT THIS PRINT IS THE PROPERTY OF LENNOX INDUSTRIES
C
ALT
NO. DATE
ALTERATIONS
ENGR
& CHKR
6/17/03 ECN T-2549: INITIAL RELEASE DM
1 6/24/03 T-2185: MODEL WAS CI1500DVF DM
2 7/11/03 T-2559: ADD ALCOVE IN NOTES AND
DEPTH-48”
LB
3 5/23/05 T-3125: UPDATE LENNOX LOGO &
MANUFACTURED AT.
JSH
4 9/8/06 T-3414; REVISED MFR’D AT DM
5 5/18/07 T-3531; REVISED MFR’D AT DM
TOLERANCE UNLESS OTHERWISE NOTED LINEAL DIM., SQUARENESS, NOTCH &
BRAKE RES. ± 1/32 ANGLES ±2°, HOLES UP TO ¼” ±.004, ¼” ±.005, ¼” TO 1” ±.010, OVER
1” ±1/64
LENNOX
®
Industries Inc. E NG INEERI NG
DEPT.
TORO NTO,
ONTARIO
DESIGN OF
STICKER - RATING PLATE
MATERIAL
SEE ABOVE
FOR FINISH SECS REFER TO ES-0049
PAINT
INSIDE
NONE
SHEET NO.
1 OF 1
DWG
NO.
PAINT
OUTSIDE
NONE
9-1452A
MATERIAL: 24M8501 QTY 1
299008016, QTY 1.021 FEET
MODEL NO.
CI1500DVF
SERIES
MANUFACTURED AT: AUBURN, WASHINGTON
FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)
0-4500 FT (0-1370 M)
4.5”
3.5”
.121
38,500
25,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINI SMUM IDEWALLS
FLOOR
2”
0”
CLEARANCES TO CEILING OR ALCOVE HEIGHT
BACK/CORNER 45°
62”
4”
COMBUSTIBLE
MATERIAL
VENT SURFACES: TOP
SIDES
BOTTOM
3”
1”
1”
ALCOVE MAXIMUM DEPTH 48”
DEGAGEMENT MUR ADJACENTS
PLANCHER
50.8mm
0mm
MINIMUM DE PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
1574.8mm
101.6mm
MATERIAUX
COMBUSTIBLES
SURFACES D’AERATION: DESSUS
COTES
BAS
76.2mm
25.4mm
25.4mm
PROFONDEUR D'ALCÔVE MAXIMALE 1219.2mm
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION: Do not operate the appliance with glass removed, cracked or broken.
Replacement of panel should be done by a licensed or qualified service person.” .”
“This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N H3706
FINAL INSPECTION BY:
ANSI Z21.88-2007
CSA 2.33-2007
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N 9-1452F
SERIAL NUMBER/NOMBRE DE SERIE
XXXXX XXXXX
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
P/N 9-1452F
DO NOT SCALE THIS PRINT THIS PRINT IS THE PROPERTY OF LENNOX INDUSTRIES INC.
MODEL NO.
CI2500DVF
SERIES
MATERIAL: 24M8501 QTY 1
299008016, QTY 1.021 FEET
A
LT
NO. DATE
A
LTERATIONS
ENGR
& CHKR
6/17/03 ECN T-2549: INITIAL RELEASE DM
1 6/24/03 T-2185: MODEL WAS CI2500DVF DM
2 7/11/03 T-2556: ADD ALCOVE IN NOTES AND
DEPTH-48”
LB
3 5/23/05 T-3125: UPDATE LENNOX LOGO &
MANUFACTURED AT.
JSH
4 9/8/06 T-3414; REVISED MFR’D AT DM
5 5/18/07 T-3531; REVISED MFR’D AT DM
TOLERANCE UNLESS OTHERWISE NOTED LINEAL DIM., SQUARENESS, NOTCH &
BRAKE RES. ± 1/32 ANGLES ±2°, HOLES UP TO ¼” ±.004, ¼” ±.005, ¼” TO 1” ±.010, OVER
1” ±1/64
LENNOX
®
Industries Inc. E NG INEERING
DEPT.
TORO NTO,
ONTARIO
DESIGN OF
STICKER - RATING PLATE
MATERIAL
SEE ABOVE
FOR FINISH SECS REFER TO ES-0049
PAINT
INSIDE
NONE
SHEET NO.
1 OF 1
DWG
NO.
PAINT
OUTSIDE
NONE
9-1452F
US
Portland
US
Portland