Jotul GF300 DV Stove User Manual


 
7
Alcove Installation
Maximum Alcove Depth: 24” (610 mm)
Minimum Alcove Width: 36 3/4” (934 mm)
Minimum Ceiling Height: 61” (1549 mm)
With Short Legs (6”): 58 3/4 (1486 mm)
* Allow 10” on left side of the appliance for complete
access to the lighting instructions and control valve.
3”
(76mm)
Right Side
Figure 3. Parallel Installation Clearances.
Figure 4. Vent adaptor centerline at minimum clearance
to corner walls.
10” *
(254 mm)
Left Side
Figure 2. Mantel and Trim Clearance specifications.
Subtract 2 1/4” with Short Legs.
2”
(51 mm)
To Rear Wall
52 1/2
1334 mm
55 1/2
1410 mm
12.5
10.25
8
5.75
3.5
18 1/2
(419 mm)
Max. Mantel Depth
Min. Mantel Depth
Minimum Ceiling or Alcove Height
61
1550 mm
54
1372 mm
58 1/2
1486 mm
57
1449 mm
28
711 mm
Max. Top Trim Depth = 1
46 1/2
1182 mm
Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove
to Combustibles:
See figs. 2-4.
Rear: 2” (51 mm)
Ceiling: 33” (838 mm)
Corner: 2” (51 mm)
Right Side: 3” (76 mm)
Left Side: 10” (254 mm) - for access to Lighting Instruction plate
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe 2” (50 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides 1” (25 mm)